Universal single-hole connection (possible to obtain a left or right figure) with a connection spacing of 50 mm allows the connection of the supply and return of the central heating to one vertical radiator collector at the same time. It has a pre-setting to limit the flow.
Connect the supply and return of the 3/4″ valve to the central heating system using fittings (not included), and to the radiator using a half-union and a copper pipe placed in it. The thermostatic insert should be on the return side of the central heating system. If this is not the case, remove the thermostatic insert from the valve body and swap the thermostatic insert with the return valve on the opposite side. Place the copper tube in the valve so that the supply liquid from the central heating leads to the radiator and fasten with half-union. Set the thermostatic head knob to the maximum position (5) and mount it on the thermostatic insert M30x1,5 mm. To ensure proper operation of the valve, installation should be performed by a qualified installer. Adjust the room temperature by setting the knob to: T (7°C), 1 (12°C), 2 (16°C), 3 (20°C), 4 (24°C), 5 (28°C). The presented temperatures are estimated.
EAN CODE: 5907710984857 PRODUCT CODE: 85436478
Connection type: | for radiator 1/2”, fitting mounting thread external – 3/4” |
Head thread: | M30x1,5 mm |
Operating temperature: | max 100℃ |
Maximum work pressure: | 10 bar |
Head temperature range: | 7℃ to 28℃ |
Head location: | on the return side |